Multi-Unit Analog

Multi-Unit Analog
Material: Titanium (Ti6Al4V ELI)
Length: 12mm
Works with: NobelActive, NobelActive TiUltra, NobelParallel CC, NobelParallel CC TiUltra, NobelReplace CC, DMDriving, DMEqual, EASYLEARN Implants
Compatible Implant Platform: Narrow Platform (NP) / Regular Platform (RP)

Details zum Produkt

The Multi-Unit Analog is a meticulously crafted, high-quality titanium alloy component, specifically designed to meet the rigorous demands of dental implant restoration procedures. This outstanding analog is forged from Ti6Al4V ELI titanium alloy, a material favored by dental professionals for its unparalleled strength, exceptional biocompatibility, and remarkable corrosion resistance.

Ti6Al4V ELI titanium alloy not only provides the Multi-Unit Analog with excellent structural stability and durability but also ensures high precision and reliability during the implant surgery process, offering solid support for the patient’s oral health. Its biocompatibility is particularly impressive, effectively reducing the risk of rejection after implantation and promoting rapid tissue healing and integration, which significantly enhances the patient’s comfort and satisfaction.

 

Key Features

  1. Titanium Alloy Structure: This Multi-Unit Analog is meticulously crafted from high-quality Ti6Al4V ELI titanium alloy, a material that not only offers exceptional strength but also remarkable flexibility, making it ideal for use in the dental field. The perfect combination of these properties ensures that the analog maintains its shape stability and durability even when subjected to the pressures of the complex oral environment.
  2. Precise Length Design: The analog is designed with a length of 12mm, which is the ideal size for most implant systems. Its precise dimensions not only assist in simulating the position and angle of the implant but also provide a more accurate reference during implant planning, thereby enhancing the accuracy and success rate of the surgery.
  3. Versatile Compatibility: This analog is highly compatible and can seamlessly integrate with a range of Nobel Biocare systems, including but not limited to NobelActive, NobelParallel CC, and NobelReplace CC. This feature makes it a flexible solution for various dental implant surgeries, catering to the personalized needs of different patients.
  4. Platform Compatibility: Whether for Narrow Platform (NP) or Regular Platform (RP), this analog adapts easily, demonstrating great versatility and flexibility. This feature allows it to accommodate various implant sizes and configurations, providing dental professionals with more options and convenience.
  5. Professional Application: This Multi-Unit Analog is specifically designed for implant placement in simulation models, helping dental technicians plan more scientifically and reasonably for multiple implant cases. Whether using NobelActive or other DentalMaster systems, this analogue ensures the accurate positioning of crowns and bridges, providing strong support for creating reliable and aesthetic restorative outcomes.

 

Multi-Unit Analog Features

  1. Precise Simulation of Implant Position and Angle:
    The Multi-Unit Analog plays a critical role in dental laboratories, as it accurately replicates the position, angle, and orientation of dental implants. This functionality allows dental technicians to perfectly simulate the implant installation when creating restorative devices (such as crowns, bridges, etc.), ensuring the precision and suitability of the final restoration.
  2. Assists in Creating Restoration Models:
    After the implant surgery is completed, dental technicians need to create a model based on the actual positioning and angle of the implants. The Multi-Unit Analog is an indispensable tool for this process. It can be precisely placed within the dental model to help technicians accurately reproduce the implant layout, ensuring that the restorative device fits perfectly onto the implant, achieving the best restoration results.
  3. Provides Multiple Connection Points Support:
    For multi-tooth implant restorations, especially when the implants are designed to be connected as a multi-unit system, the Multi-Unit Analog shows its unique advantages. It can simulate the connections between multiple implants and ensure the precise positioning and function of each implant in the restoration, thereby meeting the needs of complex implant restorations.
  4. Ensures Precise Fit of the Restoration:
    By using the Multi-Unit Analog, dental technicians can ensure the precise fit of the restoration with the implant, effectively avoiding issues like looseness or instability. This feature not only improves the stability of the restoration but also prolongs its lifespan, providing patients with a more durable and reliable outcome.

Use Cases

  1. Multiple Tooth Implants:
    When a patient requires multiple implants, the Multi-Unit Analog becomes an extremely useful tool. It helps technicians accurately replicate the configuration of the implants, ensuring coordination and stability between the multiple restorations, leading to the best possible outcome.
  2. Adjusting Implant Angles and Directions:
    In certain cases, the implant angle or orientation may not align directly. In such instances, the Multi-Unit Analog proves valuable by assisting technicians in making precise adjustments to achieve the best possible restoration results. This feature makes the Multi-Unit Analog even more practical and valuable in complex implant restorations.

 

Produkt-Tags

Anfrage senden